P16.5-1S | 15 kVA to 16.5 kVA Diesel Generator | Perkins Engine

Small Range <220 kVA P16.5-1S

Request A Price Find Dealer

Key Specs

Minimum Rating
15 kVA / 15 kW
15 kVA / 15 kW
Maximum Rating
16.5 kVA / 16.5 kW
16.5 kVA / 16.5 kW
Emissions/Fuel Strategy
Fuel Optimised
Fuel Optimised

Overview

6.8 - 25 kVA

The 6.8 - 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Benefits

Up To 2000L Extended Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Telematics Ready Stay In Control Telematics Ready

Telematics availability allows for remote access to genset controls ensuring your always in control were ever you are

Product Specifications for P16.5-1S

Minimum Rating 15 kVA / 15 kW 15 kVA / 15 kW
Maximum Rating 16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW
Emissions/Fuel Strategy Fuel Optimised Fuel Optimised
50 Hz Prime 15 kVA / 15 kW 15 kVA / 15 kW
50 Hz Standby 16.5 kVA / 16.5 kW 16.5 kVA / 16.5 kW
60 Hz Prime - / - - / -
60 Hz Standby
Frequency 50 Hz 50 Hz
Speed 1500 RPM 1500 RPM
Voltage 220-240 Volts 220-240 Volts
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Model Perkins® 404A-22G1 Perkins® 404A-22G1
Bore 84 mm (3.3 in) 84 mm (3.3 in)
Stroke 100 mm (3.9 in) 100 mm (3.9 in)
Governor Type Mechanical Mechanical
Displacement 2.2l (135.2 cu. in) 2.2l (135.2 cu. in)
Compression Ratio 23.3:1 23.3:1

P16.5-1S Standard Equipment

Engine

  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown

Cooling

  • Package mounted radiator
  • Radiator & Cooling Fan
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix

Exhaust

  • Exhaust flange outlet
  • Exhaust stub pipe and gasket

Fuel

  • 8 Hr Fuel Tank or Skidbase
  • Fuel Fittings for Local and Remote Feed

Alternator

  • IP23 Protection
  • FG Wilson Alternator
  • SHUNT Excitation
  • IP23 Protection

Mounting

  • Skid Base, Formed Steel
  • Anti-vibration mounts
  • Base, Formed Steel with Skid base or Single wall Fuel Tank
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Anti-vibration mounts
  • Battery Tray and Cables

Control Panel

  • FG100

P16.5-1S Optional Equipment

Exhaust

  • Industrial, Residential, Critical Silencers

Alternator

  • Leroy Somer Alternator
  • Quadrature Droop Kit
  • Anti-Condensation Heater and Panel Circuitry

Control Panels

  • DSE4520
  • DSE7320
  • DSE7410
  • Deep Sea DSE7420

General

  • 8 Hour, 600L, 1000L, 2000L fuel tanks
  • Dual wall fuel tanks
  • Upgrade to Standard Set for "CE" Certification
  • EEC Declaration of Conformity
  • Narrow, Wide or Skid Base
  • Sound attenuated, steel or galvanised enclosure
  • Dual wall fuel tanks

Starting/Charging

  • Lead Acid battery (Dry)

Enclosure

  • Compliance to European Community Directive 2000/14/EC
  • Super sound attenuation for residential areas
  • Totally enclosed exhaust silencing system
  • Robust and highly corrosion resistant construction

See how P16.5-1S compares against frequently compared products.