P11-6S | 10 kVA to 13 kVA Diesel Generator | Perkins Engine

Small Range <220 kVA P11-6S

Request A Price Find Dealer

Key Specs

Minimum Rating
10 kVA / 10 kW
10 kVA / 10 kW
Maximum Rating
13 kVA / 13 kW
13 kVA / 13 kW
Emissions/Fuel Strategy
EU3a Emissions Compliant
EU3a Emissions Compliant

Overview

6.8 - 25 kVA

The 6.8 - 25 kVA range of generator sets is designed to power your every need. Suitable for use in diverse applications including construction, residential, retail and telecommunications, this range has been redesigned for optimum performance in some of the harshest and most remote environments. Available with a metal or polymer enclosure offering, this range is designed to withstand the test of time.

Benefits

Up To 2000L Extended Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Telematics Ready Stay In Control Telematics Ready

Telematics availability allows for remote access to genset controls ensuring your always in control were ever you are

Product Specifications for P11-6S

Minimum Rating 10 kVA / 10 kW 10 kVA / 10 kW
Maximum Rating 13 kVA / 13 kW 13 kVA / 13 kW
Emissions/Fuel Strategy EU3a Emissions Compliant EU3a Emissions Compliant
50 Hz Prime 10 kVA / 10 kW 10 kVA / 10 kW
50 Hz Standby 11 kVA / 11 kW 11 kVA / 11 kW
60 Hz Prime 12 kVA / 12 kW 12 kVA / 12 kW
60 Hz Standby 13 kVA / 13 kW 13 kVA / 13 kW
Frequency 50 / 60 Hz 50 / 60 Hz
Speed 1500 or 1800 RPM 1500 or 1800 RPM
Voltage 220-240 Volts 220-240 Volts
50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
50 Hz Standby Rating Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Engine Model Perkins® 403D-15G Perkins® 403D-15G
Bore 84 mm (3.3 in) 84 mm (3.3 in)
Stroke 90 mm (3.5 in) 90 mm (3.5 in)
Governor Type Mechanical Mechanical
Displacement 1.5l (91.3 cu. in) 1.5l (91.3 cu. in)
Compression Ratio 22.5:1 22.5:1

P11-6S Standard Equipment

Engine

  • Air Cleaner
  • Lube oil drain valve
  • Engine filled with lubrication oil
  • High Coolant Temperature Shutdown
  • Low Oil Pressure Shutdown

Cooling

  • Package mounted radiator
  • Radiator & Cooling Fan
  • Coolant Drain Valve
  • Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
  • Cooling System filled with Coolant mix

Exhaust

  • Exhaust flange outlet
  • Exhaust stub pipe and gasket

Fuel

  • 8 Hr Fuel Tank or Skidbase
  • Fuel Fittings for Local and Remote Feed

Alternator

  • FG Wilson Alternator
  • SHUNT Excitation
  • IP23 Protection

Control Panel

  • FG100

Mounting

  • Base, Formed Steel with Skid base or Single wall Fuel Tank
  • Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
  • Anti-vibration mounts
  • Battery Tray and Cables

P11-6S Optional Equipment

Exhaust

  • Industrial, Residential, Critical Silencers

Alternator

  • Leroy Somer Alternator
  • Quadrature Droop Kit
  • Anti-Condensation Heater and Panel Circuitry

Control Panels

  • DSE4520
  • DSE7320
  • DSE7410
  • Deep Sea DSE7420

Starting/Charging

  • Lead Acid battery (Dry)

General

  • Upgrade to Standard Set for "CE" Certification
  • EEC Declaration of Conformity
  • Narrow, Wide or Skid Base
  • Sound attenuated, steel or galvanised enclosure
  • Dual wall fuel tanks

Enclosure

  • Compliance to European Community Directive 2000/14/EC
  • Super sound attenuation for residential areas
  • Totally enclosed exhaust silencing system
  • Robust and highly corrosion resistant construction